YC6K
300kW Marine Diesel Genset
YC6K
300kW Marine Diesel Genset
Product Features
1. High Reliability
The overhaul time of the engine can reach 30,000 hours.
2. Energy Saving and Environmental Friendliness
Fuel consumption is more than 10% less than that of traditional engines. The application of full electronically-controlled technology makes the product meet IMO II emission standards or above.
3. High Safety
Electronically-controlled self-diagnosis protection and fault operation protection. Advanced technology and design: pure electronic control, customizable.
4. Optimal Set
Bosch, Honeywell, Mahle, Federal-Mogul, Gates, and other world's top internal combustion engine parts suppliers.
Product Parameters
Name | Main Technical Parameters | |
Genset model | CCFJ300J-W | |
Power supply type | Three-phase AC | |
Rated power kW | 300 | |
Rated voltage V | 400 | |
Rated current A | 541.3 | |
Rated frequency (Hz) | 50 | |
Rated power factor (COSφ) | 0.8 (Lag) | |
Rated speed r/min | 1500 | |
Absolute value of steady-state voltage regulation % | ≤2.5 | |
Absolute value of transient voltage deviation (%) | Sudden unloading 60% Rated current | ≤20 |
| Sudden load 60% Rated current | ≤15 |
Voltage stabilization time (s) | ≤1.5 | |
Absolute value of voltage fluctuation rate % | ≤1 | |
Absolute value of transient speed regulation % | Sudden load 0-50% | ≤10 |
| Sudden load 50-100% |
|
| Sudden unloading 100%-0 |
|
Transient speed regulation stabilization time s | ≤5 | |
Steady-state speed regulation % | ≤5 | |
Absolute value of speed fluctuation rate % | ≤0.5 | |
Insensitivity of genset speed governing system % | ≤0.5 | |
Fuel consumption rate under rated conditions (g/(kW·h)) | ≤205 | |
|
| |
Specific oil consumption g/(kW·h) | ≤0.1 | |
Fuel grade | Summer: 0#, 10# light diesel of GB 19147-2016 premium grade or first grade; | |
| Winter: 0#, -10#, -20# and -35# light diesel of GB 19147-2016 premium grade or first grade (selected based on the ambient temperature) | |
Oil grade | Summer: 40CF, 15W/40CF; | |
| Winter: 30CD, 10W/30CD or other diesel engine oil that is not inferior to Grade CF in GB 11122-2006 and suitable for the environment. | |
Start mode | Electric start | |
Cooling mode | Internal circulation: Closed circulating water cooling, External circulation: Open water cooling | |
Connection mode of motor winding | Three-phase four-wire | |
Operating mode of genset | Continuous | |
Operating environment conditions | Ambient temperature | 45°C |
| Outboard water temperature | 32°C |
| Inclination angle | Heel: 15°; roll: 22.5°; trim: 7.5°; pitch: 10° |
Temperature rise | Thermal classification A | 55°C |
| Measurement method R |
|
Short circuit | The alternator and its excitation system can maintain at least 3 times the rated current for at least 2s under steady-state short-circuit conditions. | |
Overload | 50% overcurrent; 2 min | |
Fuel engine model | YC6K490L-C20 | |
Rated power of diesel engine (kW) | 360 | |
Alternator model | SB-HW4.D-300 | |
| (SAE1-14) | |
Rated power of motor (kW) | 300 | |
Genset weight (kg) | 2600 | |
Dimension (Length × Width × Height) mm | 2540×1170×1350 | |
Note: Dimension (L*W*H) may vary with the configuration. | ||